Creating a Disk Array – Express (CLU)
To create a disk array using the Express feature:
1. Main Menu >> Disk Array Management >> Create New Array >> Conguration
Method and press the spacebar to toggle to Express.
2. Highlight the following options and press to spacebar to choose Yes or No:
Redundancy
Capacity
Performance
Spare Drive
3. Highlight Number of Logical Drives and press the backspace key to erase the current value,
then enter the number of logical drives you want.
4. Highlight Application Type and press the spacebar to toggle though the applications and
choose the best one for your disk array.
File Server
Video Stream
Transaction Data
Transaction Log
Other
5. Press Control-A to save your settings and move to the next screen.
6. Review the proposed conguration of disk array and logical drives.
To accept the proposed conguration and create the disk array and logical drives, highlight
Save Conguration and press Enter.
To reject the proposed conguration, highlight Return to previous menu and press Enter.
53
Managing with CLUVess A3340 Product Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology Vess A3340 and is the answer not in the manual?

Promise Technology Vess A3340 Specifications

General IconGeneral
BrandPromise Technology
ModelVess A3340
CategoryNetwork Hardware
LanguageEnglish

Related product manuals