EasyManuals Logo

Promise Technology Vess A3340 User Manual

Promise Technology Vess A3340
241 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
Rebuilding a Disk Array (CLU)
Before you can rebuild, you must have a replacement or target physical drive of adequate capacity
for your disk array.
To rebuild a disk array:
1. Main Menu >> Disk Array Management
2. Highlight the disk array you want and press Enter.
3. Highlight Background Activities >> Rebuild
Default source and target drives are shown with possible alternative choices.
4. To choose different drive, highlight the drive, press the backspace key to remove the current
number, then type a new number.
5. Highlight Start and press Enter.
Running Media Patrol on a Disk Array (CLU)
Media Patrol is a routine maintenance procedure that checks the magnetic media on each disk drive.
If Media Patrol encounters a critical error, it triggers PDM if PDM is enabled on the disk array.
59
Managing with CLUVess A3340 Product Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology Vess A3340 and is the answer not in the manual?

Promise Technology Vess A3340 Specifications

General IconGeneral
BrandPromise Technology
ModelVess A3340
CategoryNetwork Hardware
LanguageEnglish

Related product manuals