EasyManua.ls Logo

Promise Technology Vess A3340 - Software Management (CLU)

Promise Technology Vess A3340
241 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Running Redundancy Check (CLU)
Redundancy Check is a maintenance procedure for logical drives in fault-tolerant disk arrays that
ensures all the data matches exactly.
To run Redundancy Check:
1. Main Menu >> Logical Drive Management
2. Highlight the logical drive you want and press Enter.
3. Highlight Background Activities >> Start Redundancy Check
The redundancy check parameters appear.
• Auto Fix – Corrects inconsistencies automatically
• Pause On Error – Pauses the Redundancy Check when an error is found
To change a parameter, highlight it and press the backspace toggle between Yes and No.
4. Highlight Start and press Enter.
If necessary, you can pause and resume or stop and restart the Redundancy Check. You can
use the logical drive while Redundancy Check is running.
For Redundancy Check rate, see “Making Background Activity Settings (CLU)” on page 74.
Locating a Logical Drive (CLU)
This feature helps you identify the physical drives assigned to the logical drive you are working with
in the CLU. To locate a logical drive:
1. Main Menu >> Logical Drive Management
2. Highlight the logical drive you want and press Enter.
3. Highlight Locate Logical Drive and press Enter.
The drive carrier status LEDs ash for one minute.
72
Vess A Class NVR Storage Appliance Promise Technology

Table of Contents

Related product manuals