MVI56E-MCMR ControlLogix Platform Reference
Modbus Communication Module with Reduced Data Block User Manual
ProSoft Technology, Inc. Page 143 of 223
6.2 Specifications
The MVI56E Modbus Master/Slave Communication Module with Reduced Data
Block allows users to integrate Modbus devices and networks into the Rockwell
Automation
®
ControlLogix
®
architecture.
Compatible devices include not only Modicon
®
PLCs (almost all support the
Modbus protocol) but also a wide assortment of processors, HMI displays,
SCADA systems and field devices made by a variety of manufacturers. The
module acts as an input/output module between the Modbus network and the
ControlLogix processor. The data transfers between the module and the
processor are asynchronous from communications on the Modbus network. A
5000-word register space in the module hold the data to be exchanged between
the processor and the Modbus network.
6.2.1 General Specifications
Backward-compatible with previous MVI56-MCMR versions
Single-Slot, 1756 ControlLogix
®
backplane compatible
10/100 Mbps Ethernet port with Auto Cable Crossover Detection
User-definable module data memory mapping of up to 5000, 16-bit registers
CIPconnect
®
-enabled network configuration and diagnostics monitoring using
ControlLogix 1756-ENxT modules and EtherNet/IP
®
pass-thru
communications
Reduced I/O image size designed specifically to optimize remote rack
implementations
ProSoft Configuration Builder (PCB) software supported, a Windows-based
graphical user interface providing simple product and network configuration
Sample Ladder Logic and Add-On Instruction (AOI) used for data transfers
between module and processor
4-character, scrolling LED display of status and diagnostic data in plain
English
ProSoft Discovery Service (PDS) software finds the module on the network
and assigns a temporary IP address to facilitate module access
Personality Module (non-volatile CF card) to store network configuration
allowing quick in-the-field product replacement by transferring the CF card