149
A minimum of three measurement positions are required to obtain results, but
it is recommended that a maximum number of measurement points be taken to
improve the quality of results.
7.5 Results
When measurement is complete, press w to view results.
Sign convention (for vertical machines)
POSITIVE GAP opens towards 0:00 or 3:00
POSITIVE OFFSET if the top coupling half is offset towards 0:00 or 3:00
Cycle through the coupling results and the flange correction positions using either
w, f or g.
H
Note
The ‘all-in-one’ results
screen shows the coupling
gap and offset values in the
0-6 and 3-9 directions for
short flex coupling and the
flange correction values.
H
Note
Vertical flanged machines

Table of Contents