5.13.8 Points to observe during Live Move
1. Have shafts accidentally moved (rotated)?
The shafts, sensor and laser MUST remain steady during the entire Live Move
procedure. Should the shaft move from the set position while in Live Move, the angle
adjustment window comes up indicating the angle to which the shaft has rotated.
The shafts must be rotated back into the narrow green sector.
Live Move resumes automatically when the shafts are rotated back into this
sector.
2. Extending measurement range
If the hint on the screen below appears during Live Move, then the laser beam has
drifted out of detection range due to great misalignment or long beam travel.
In this case, the measurement range can be extended as described in section 6.2.1.