Pict.
9
-
Perfect
Prusa
logo
first
layer
6.3.10.2 Check probe height (kit only)
If the first layer seems inconsistent between multiple prints, the probe might be
too high. Lower it slightly. Loosen the two screws on the probe holder to make
adjustments. By rotating the probe clockwise, it will lower at 1mm per turn. It
is very handy for precise adjustments, but it can also be pushed in and out when set screws
are loosened completely. Then try again Calibrate XYZ. Keep in mind, the probe must be
always higher than the nozzle tip, otherwise it will catch on prints.
Pict.
10
-
Probe
response
diagram.
Now you are done!
24