Totaliser Window
This window displays the current value of the resettable and system
totaliser. The totaliser will appear during Run mode when the totaliser
screen is selected. Pressing the left-hand arrow key from the Flow window
will display the Totaliser window.
Totaliser (R)
This displays the current value of the resettable totaliser which appears
during run mode. The resettable totaliser can be reset whilst in Run mode
by pressing the F4 key when you are in the totaliser screen. The below pop
up window will appear:
Press Enter to reset or cancel to reject the request.
Totaliser (S)
Displays the current value of the non-resettable totaliser. During run mode,
the system totaliser is viewed at the bottom of the Totaliser screen. Unlike
the resettable totaliser this can only be reset by accessing the “Settings 2-
Controller’” menu and choosing option 6”. Press enter on the option Reset
‘sys’ totaliser and enter the value ‘1’ to confirm reset.