Environment and Requirements 45
Chapter 5
Environment and Requirements
This chapter provides the following information:
QXS 2U/5U Environmental Requirements
This section contains the following information:
• QXS 2U/5U Ambient Temperature and Humidity Requirements
• QXS 2U/5U Additional Environmental Requirements
QXS 2U/5U Ambient Temperature and Humidity Requirements
Tab l e 20 provides the 2U/5U ambient temperature and humidity requirements.
• QXS 2U/5U Environmental Requirements • Safety Compliance
• QXS 2U/5U PSU Specifications • EMC Compliance
• International Standards • AC Power Cords
• Potential for Radio Frequency Interference • Recycling of Waste Electrical and Electronic
Equipment (WEEE)
• European Regulations
Ta bl e 2 0 QXS 2U/5U Ambient Temperature and Humidity Requirements
Specification Temperature Range Relative Humidity Maximum Wet Bulb
Operating RAID Chassis: 5ºC to 35ºC
(41ºF to 95ºF)
Expansion Chassis: 5ºC to
40ºC (41ºF to 104ºF)
20% to 80% non-con-
densing
28ºC
No-operating (shipping) -40ºC to +70ºC (-40ºF to
+158ºF)
5% to 100% non-precipi-
tating
29ºC