Appendix A SFC6400A/SFC1450A Synthesized Frequency Upconverter
A-10 TM106 Rev. 1.1
A backup converter in a 1:8 Switch Configuration will return the following string of information:
<cr><lf>
abcdefgh = Priority settings for converters 1 - 8 respectively
0 = None. Backup will ignore converter
1 = Highest priority
8 = Lowest Priority
<cr><lf>
n = Used with manual backup command MANBACK as follows:
0 = Places the Backup in Standby mode, all Primes
online
1 - 8 Specifies the Prime to be taken offline and replaced
by the Backup
<cr><lf>
<cr><lf> {End of transmission}
A backup converter in a 1:1 Switch Configuration will return the following string of information:
<cr><lf>
There are no data specific commands for the backup converter in the one for one switch
configuration
<cr><lf>
<cr><lf> {End of transmission}
A.4 Show Received Signal Strength Command (Upconverter Only)(S, P1:1,
P1:8)
This command will cause the converter to output the Received Signal Strength.
@01/SHOWRSS<cr>
The converter will return the following:
<cr><lf>
RSS: vv {vv = value for Received Signal Strength}
<cr><lf>
<cr><lf> {End of transmission}
A.5 Show Priority Command (B1: 8)
This command returns the priority settings for all 8 of the prime converters. The command is as
follows:
@01/SHOWPRI
The converter will return the following:
<cr><lf>
Converter 1 2 3 4 5 6 7 8
Priority a b c d e f g h {abcdefgh = Priority settings for converters 1 - 8
respectively}
<cr><lf> {End of transmission}