SFC6400A/SFC1450A Synthesized Frequency Upconverter Appendix A
TM106 Rev. 1.1 A-23
A.35 Dump Calibration Table Set (All)
This command returns the contents (DAC values for all gains) of the Power Calibration Table for the
given Frequency Index. The command is as follows:
@01/DMPCALff<cr>
where:
ff {Index into the frequency array portion of the table}
If successful, the converter will return the following string:
<cr><lf>
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
<cr><lf>
<cr><lf> {End of transmission}
where:
ffff.f {f = frequency for channel entry}
sgg.g {s = ‘+’ or ‘-‘ : gg.g = Gain for channel entry}
A.36 Get Current DAC Value (All)
This command returns the DAC value in use for the unit’s current configuration (Values of
Frequency and Gain). The command is as follows:
@01/CURDAC<cr>
If successful, the converter will return the following string.:
<cr><lf>
DAC Value = dddd {dddd = DAC Value}
<cr><lf>
<cr><lf> {End of transmission}
A.37 Get DAC Value for Frequency and Gain (All)
This command returns the DAC value to be used for the given values of frequency and gain. The
command is as follows:
@01/DACFORffff.f gg.g<cr>
where:
ffff.f {f = frequency }
sgg.g {s = ‘+’ or ‘-‘ : gg.g = Gain }
If successful, the converter will return the following string.:
<cr><lf>