SFC6400A/SFC1450A Synthesized Frequency Upconverter Appendix A
TM106 – Rev. 1.1 A-19
@01/ERASE<cr>
If successful, the converter will not return a string.
A.20 Restart (All)
This command allows the user to reset/restart the converter. The command is as follows:
@01/RESTART<cr>
If successful, the converter will not return a string.
A.21 Learn (B1: 1, B1: 8)
In a 1:1 Switch configuration, this command will cause the backup converter to ‘Learn’ about the
Prime converter.
In a 1:8 configuration, the backup converter will ‘Learn’ about the Prime converters that have a
priority >0. As the backup converter polls the Prime(s), the learning status will be output via the
serial port. The command is as follows:
@01/LEARN<cr>
A backup converter in a 1:1 Switch Configuration will return one of the following strings of
information:
<cr><lf>
Learning FAILED because the Prime gave an invalid response/Prime did not
respond/Prime's incompatible with the Backup/Prime's RF is turned off}
<cr><lf> {End of transmission}
<cr><lf>
Prime converter was successfully learned
<cr><lf> {End of transmission}
A backup converter in a 1:8 Switch Configuration will return the following string of information:
<cr><lf>
Converter 1 {FAILED because of an invalid response/FAILED because
it did not respond/FAILED because it's incompatible with
the backup/FAILED because it's RF is turned off/was
successfully learned/was not selected}
Converter 2 {FAILED because of an invalid response/FAILED because
it did not respond/FAILED because it's incompatible with
the backup/FAILED because it's RF is turned off/was
successfully learned/was not selected}
Converter 3 {FAILED because of an invalid response/FAILED because
it did not respond/FAILED because it's incompatible with
the backup/FAILED because it's RF is turned off/was
successfully learned/was not selected}
Converter 4 {FAILED because of an invalid response/FAILED because
it did not respond/FAILED because it's incompatible with