EasyManua.ls Logo

Radyne ComStream SFC6400A - Converter Menu Options and Parameters; Front Panel Control Screen Menus; Main Menus

Default Icon
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SFC6400A/SFC1450A Synthesized Frequency Upconverter User Interfaces
TM106 Rev. 1.1 4-5
4.2 Front Panel Control Screen Menus
The complete set of SFC Upconverter Front Panel Control Screens are contained within the
following Main Menus:
4.2.1 Main Menus
Converter Menu Options and Parameters
Switch Menu Options and Parameters
Monitor Menu Options and Parameters
Alarms Menu Options and Parameters
System Menu Options and Parameters
Test Menu Options and Parameters
4.2.2 Converter Menu Options and Parameters
FREQUENCY (GHz): {5895 6425 GHz} C-Band, Normal
{5845 6650 GHz} C-Band, Extended
{6.725 7.025 GHz} C-Band, India
{14.0 14.5 GHz} Ku-Band, Normal
{13.75 14.50 GHz} Ku-Band, Extended
Sets the RF output frequency. The available range
depends upon the Converter model.
CHNL GAIN (dB): {-20.0 to +30.0, dependent upon input attenuation}
Sets the Channel Gain in 0.1dB steps.
CARRIER CNTRL: {ON, OFF}
Allows the user to turn the carrier on/off.
INPUT ATTEN: {0 - 30}
Sets the input attenuation in 1 dB steps.
CURRENT CHNNL: {01 30}
Selects the current channel of the unit. Each channel
allows entering of an independent set of parameters
(Frequency, Gain, etc.). For example, Channel 1
Frequency might be set to 5.9 GHz and Channel 2 could
be set to 6.0 GHz. Any of the other parameters could be
different as well. The advantage is that by changing the
channel number, a completely different setup can be
achieved.

Table of Contents