User Interfaces SFC6400A/SFC1450A Synthesized Frequency Upconverter
4-12 TM106 Rev. 1.1
Indicates a fault if the +15V System Supply Voltage is
outside a fixed range.
- 15V FAULT: {PASS, FAIL/UNMASKED, MASKED}
Indicates a fault if the -15V system supply voltage is
outside a fixed range.
LATCHED ALRM: The Latched Alarm Menu structure is identical to the
Active Alarms. However, if any alarm is triggered it will be
Latched. For example, if an External Reference is
disconnected from the rear panel, an LO Fault will be
reported while the LO regains lock. After the LO recovers,
even though the Active Alarm no longer reports the alarm,
the Latched Alarm will still display <FAIL>. In other
words, the alarm was latched.
CLEAR ALARMS
(ENT = Y,CLR = N): Pressing <ENTER> will clear all of the Latched Alarms
currently stored.
4.2.6 System Menu Options and Parameters
CONTROL MODE: {FT PANEL, TERMINAL, COMPUTER, ETHERNET}
Sets the Control Mode of the Upconverter.
DATE: Allows the user to enter the date in DD/MM/YY format.
TIME: Allows the user to enter the time in HH:MM:SS format.
FRONT PANEL:
LEVEL: {OFF, LOW, MID, HIGH}
Allows the user to set the backlight intensity of the LCD
display.
TIMEOUT: {00 - 99}
Allows the user to set the length of inactive time (in
seconds) after which the display backlight shuts off
automatically. Entering 00 allows the backlight to remain
on continuously.
KEY CLICK: {OFF, ON}
Allows the user turn an audible key click on/off.
TERMINAL:
TERM. BAUD: {2400, 9600, 19200}
Allows the user to set the baud rate for terminal port
communication.
EMULATION: {ADDS VP, VT100, WYSE 50}
Allows the user to set the terminal emulation mode.