Appendix A SFC6400A/SFC1450A Synthesized Frequency Upconverter
A-8 TM106 – Rev. 1.1
Prime 3 is {not selected/Online with a Priority = n/Online and Faulted
with a Priority = n/Offline and Faulted with a Priority =
n/Offline and Available with a Priority = n}
Prime 4 is {not selected/Online with a Priority = n/Online and Faulted
with a Priority = n/Offline and Faulted with a Priority =
n/Offline and Available with a Priority = n}
Prime 5 is {not selected/Online with a Priority = n/Online and Faulted
with a Priority = n/Offline and Faulted with a Priority =
n/Offline and Available with a Priority = n}
Prime 6 is {not selected/Online with a Priority = n/Online and Faulted
with a Priority = n/Offline and Faulted with a Priority =
n/Offline and Available with a Priority = n}
Prime 7 is {not selected/Online with a Priority = n/Online and Faulted
with a Priority = n/Offline and Faulted with a Priority =
n/Offline and Available with a Priority = n}
Prime 8 is {not selected/Online with a Priority = n/Online and Faulted
with a Priority = n/Offline and Faulted with a Priority =
n/Offline and Available with a Priority = n}
Backup is {Faulted, Warming up/Faulted/Available/Online for Prime
n}
{n = backed up prime converter}
<cr><lf>
Converter 1 2 3 4 5 6 7 8
Learn Status {F/- } {for 1 - 8} (Dash = Pass, F = Fail)
Polling Status {F/- } {for 1 - 8} (Dash = Pass, F = Fail)
Relay Status {F/- } {for 1 - 8} (Dash = Pass, F = Fail)
Switch is in {Manual mode/Auto mode}
<cr><lf> {End of transmission}
A.3 Data (All)
This command returns the applicable data formats for the various commands. The command is as
follows:
@01/DATA
A single converter, prime converter in a 1:1 switch configuration or prime converter in a 1:8 Switch
Configuration will return the following string of information:
For Upconverter:
<cr><lf>
cc = channel (01 to 30)
gg.g = gain (-20.0 to +30.0) depending on Input Attenuation
s = sign (+ or -)
ffff = frequency MHz (ffff.0 to ffff.0) {ffff.0 = frequency in MHz, low end to high end}
t = Kilohertz step ( 0 to 7 for 000 - 875 in 125 kHz increments)
aa = Input Attenuation (00 to 30)
<cr><lf>
<cr><lf> {End of transmission}
For Upconverter: