TRACe Subsystem EM510
5.115 4065.7763.32-01.00
TRACe|DATA
Note:
Instead of command word TRACe, DATA may be used as well.
. :CATalog?
Query about all defined trace names.
Note:
IFPAN trace is only available with the software option EM510IM (ITU Measurement) or software option
EM510SU (Spectrum Unit) installed.
Parameters:
none
Result:
"MTRACE", "ITRACE", "IFPAN", "SSTART", "SSTOP", "UDP"
TRACe
. [:DATA] <trace_name>, <numeric_value> {, <numeric_value>} | <block>
Writing data to a trace.
Note:
Only the suppress traces can be written to.
Error messages:
If the trace name is unknown or not identical with a suppress trace, error -141 "Invalid character data" is
generated.
If too many data are loaded in a suppress trace, error -223 "Too much data" is generated.
Parameter:
<trace-name> name of the trace to be written to as <Character Data>
SSTART
<numeric_value> list of frequencies. If the list is not complete, the rest of the trace
is filled with 0.
Note:
In contrast to the SCPI standard a single value is not used for the
complete trace!
<block> As an alternative to the frequency list a <Definite Length
Block> can be transmitted with the following structure:
Frequency list with frequencies in Hz, 4 bytes per frequency.
*RST state:
No change of trace contents at *RST.
Example:
TRACe SSTART, 123.475 kHz, 118000, 98.550 kHz