EasyManua.ls Logo

R&S EM510 - Status:trace Register

R&S EM510
183 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EM510 Remote Control via LAN
4065.7763.32-01.00 5.138
5.5.3.7 STATus:TRACe Register
This register contains information on ambiguous states of the traces MTRACE, ITRACE, IFPAN,
SSTART and SSTOP.
It can be queried with the commands STATus:TRACe:CONDition? or STATus:TRACe[:EVENt]?.
Table 5-6: Bit allocation of STATus:TRACe register
Bit No. Meaning
0 MTRACE not empty
This bit is set if the MTRACE contains at least one measured value.
1
MTRACE limit exceeded
This bit is set if the number of measured values contained in the MTRACE exceeds the threshold given by the
command TRACe:LIMit[:UPPer] MTRACE.
2
MTRACE total full
This bit is set if the MTRACE is loaded with the maximum number of measured values.
3 ITRACE not empty
This bit is set if the ITRACE contains at least one information value.
4 ITRACE limit exceeded
This bit is set if the number of measured values contained in the ITRACE exceeds the threshold given by the
command TRACe:LIMit[:UPPer] ITRACE.
5 ITRACE total full
This bit is set if the ITRACE is loaded with the maximum number of information values.
6 SSTART changed
This bit is set if one or several start frequencies of the current suppress table have changed.
7 SSTOP changed
This bit is set if one or several stop frequencies of the current suppress table have changed.
8 IFPAN not empty
This bit is set if at least one measured value is stored under IFPAN.
9
IFPAN Limit exceeded
This bit is set if the number of measured values stored under IFPAN exceeds the threshold set by
TRACe:LIMit[:UPPer] IFPAN.
10
IFPAN total full
This bit is set if the maximal number of measured values is stored under IFPAN.

Table of Contents