R&S EM510 - STATus:EXTension Register and Change Bits

R&S EM510
183 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control via LAN EM510
5.139 4065.7763.32-01.00
5.5.3.8 STATus:EXTension Register
This register contains in the CONDition part information on different receiver states which cannot be
assigned to the other registers. Information about the actions the unit has carried out since the last read
out are stored in the EVENt part. The corresponding registers can be queried with the commands
STATus:EXTension:CONDition? or STATus:EXTension[:EVENt]? .
Table 5-7: Bit allocation of STATus:EXTension register
Bit No. Meaning
0 RX-Data changed
This bit is set if the receiver data were changed by another remote client (see also "Data Memory" on page
5.127).
1
FSCAN-Configuration changed
This bit is set if the FSCAN data were changed by another remote client (see also "Data Memory" on page
5.127).
2 Signal changed
This bit is set if the received signal changes in level or offset.
3 COR active
This bit is set if the COR relay becomes active.
4 SIGNal > THReshold
This bit is set if the signal level is above the squelch threshold (precondition: squelch is switched on).
5 INPut:ATTenuation:STATe
This bit is set if the input attenuator is switched on.
7 Reserved
8 RX-Settings changed
This bit is set if a parameter was changed by another remote client in the data set "miscellaneous".
9 MSCAN-Configuration changed
This bit is set if the MSCAN data set is changed by another remote client .
10 Reserved
12 MEMory-Data changed
This bit is set if a memory data was changed by another remote client.
13 MEMory-Parameter changed
This bit is set if the query bit was changed by another remote client.
14 PSCAN-Configuration changed
This bit is set if the PSCAN data set is changed by another remote client (PSCAN is an option).