EasyManua.ls Logo

R&S EM510 - ROUTe Subsystem: Signal Path Management

R&S EM510
183 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EM510 ROUTe Subsystem
4065.7763.32-01.00 5.56
5.3.14 ROUTe Subsystem
Two signal path switches (signal routing) are equipped in the EM510.
The command ROUTe without numeric suffix or with numeric suffix 1 is used for the antenna selector 1
to 99.
The command ROUTe with numeric suffix 2 is used for the crosspoint switch for Gigacast, FPDP and
the regenerating paths.
ROUTe
. :CLOSe <channel_list>
Selection of an antenna; the previous antenna has to be switched off with ROUTe:OPEN:ALL (also see
ROUTe:SELect)
Error message:
If more than one antenna is to be selected, an execution error -221,"Settings conflict" will be
generated.
Parameters:
<channel_list> may contain max. one number (0 to 99)
*RST state:
@1
Example:
ROUTe:CLOSe (@23)
. :CLOSe? <channel_list>
Query about whether the corresponding antenna has been selected.
Parameters:
<channel_list> contains a value for each antenna number to be queried
Result:
0 for each non-selected antenna number
1 for each selected antenna number
Example:
ROUTe:CLOSe? (@2, 10:12, 23) -> 0,0,0,0,1
. . :STATe? [MINimum|MAXimum]
Query about the antenna that has been selected.
Parameters:
none query about the currently selected antenna
MINimum|MAXimum query about the lowest|highest antenna number
Result:
Antenna number as a <Definite Length Block>
Example:
ROUTe:CLOSe:STATe? -> #15(@23)

Table of Contents