EasyManua.ls Logo

Rauch AXIS H EMC Series - Maintenance of the Hydraulic System

Rauch AXIS H EMC Series
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AXIS-H EMC/AXIS-H EMC+W
Check: Disc speed sensors
RAUCH Landmaschinenfabrik GmbH D-76547 Sinzheim
Customer service hotline: +49 (0)7221 985 250
E-mail: service@rauch.de
Page
2
of
2
29.10.2014
Chapter 660
Manual test
Switch off the tractor.
Secure the spreader against falling.
Turn the spreading disc manually by 1
rotation.
16 pulses/rotations must be
displayed.
If the right spreading disc is rotated, pulses
must be displayed on the right-hand side.
Test with running spreader
Ensure that no one is in the danger area of the machine.
Tractor running, active oil supply to the tractor.
Under PWM (%), enter a value of approx.
30-60%.
Start spreader discs.
Note: Due to the tolerances of the
proportional valves, the speed values on
the left and right-hand side will not be
identical.
Speed and impulses have to increase
uniformly without jumps.
Counter:
Idle 1: Number of all idle measurements
since resetting
Idle 2: Number of idle measurements
performed with alarm 31