AXIS-H EMC
Flow factor control sluggish or not
possible
RAUCH Landmaschinenfabrik GmbH D-76547 Sinzheim
Customer service hotline: +49 (0)7221 985 250
E-mail: service@rauch.de
Page
1
of
1
29.10.2014
Chapter 760
Mode of operation: AUTO km/h +
AUTO
kg
Switch the operating mode in the
machine settings menu
Highly fluctuating forward speed display
In the service menu, increase the
velocity filter under control parameters
=>
see chapter 3
+ Forward speed via GPS
+ Forward speed via retrofitted low-pulse
sensor
+ Forward speed via tractor bus system
Recommendation: Set the filter to 6-8
+ Disc speed fluctuation
+ Disc speed is not achieved
For one idle measurement, the speed
fluctuation must not exceed 3 % of the
disc speed.
+ For TWS spreaders, the value can be
increased to 5 %. To do so, increase the
press tolerance in the control parameters
in the service menu.
=> see chapter 3
+ Check the hydraulic system of the
tractor
+ Modification to constant current
operation
+ The motor speed of the tractor should
always be at least 1500 1/min, also for
larger hydraulic systems
+ Disc speed fluctuation
+ Disc speed is not achieved
+ Check the disc speed sensors
+ Check the cable harness and plug for
corrosion

Table of Contents