EasyManua.ls Logo

Rauch AXIS H EMC Series - 770_Wurfscheibendrehzahl_unruhig_EN(UK)

Rauch AXIS H EMC Series
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AXIS-H EMC
Disc speed fluctuation
RAUCH Landmaschinenfabrik GmbH D-76547 Sinzheim
Customer service hotline: +49 (0)7221 985 250
E-mail: service@rauch.de
Page
1
of
1
29.10.2014
Chapter 770
Sufficient oil in the tractor
Tractor motor speed at least 1400 1/min
Constant current: Tractor control unit configuration
Load Sensing: Sufficient cross-section of pressure, return and LS lines
Coupling plug of the LS line correctly connected
+ Spreading disc speed fluctuating when
idling
+ Proportional valve venting
=> see
chapter 4
1
+ The spreading disc speed falls or
starts to fluctuate if the fertiliser comes
into contact with the spreading disc
+ Sufficient tractor power supply (voltage
drop if the electric agitator is activated)
+ Sluggish agitator drive
+ Corroded machine cable harness
2
+ The spreading disc speed falls or
starts to fluctuate if the fertiliser comes
into contact with the spreading disc
+ LS system: LS signal of the spreader
too high/Tractor reacts very sensitively to
the LS signal => Install LS blind
=> see
chapter 4
4
+ The spreading disc speed falls or
starts to fluctuate if the fertiliser comes
into contact with the spreading disc
Subject to technical consultation by
Rauch
+ By changing the parameters, the
controller behaviour for spreading disc
control can be influenced
3
+ The spreading disc speed falls or
starts to fluctuate if the fertiliser comes
into contact with the spreading disc
+ Highly uneven terrain (fertiliser
bounces on the spreading disc)

Table of Contents