AXIS-H EMC
Alarm messages
RAUCH Landmaschinenfabrik GmbH D-76547 Sinzheim
Customer service hotline: +49 (0)7221 985 250
E-mail: service@rauch.de
Page
2
of
3
29.10.2014
Chapter 710
No. Message in display Meaning and possible cause
18
Blockade in drop point
setting.
The actuator for the drop point setting
cannot reach the set value it is to be
moved to.
Blockade
No position message
Calibration test
19 Defective drop point setting. The actuator for the drop point setting
cannot reach the set value it is to be
moved to.
No position message
20 Error regarding LIN-Bus
participant: Name.
Communication problem.
Defective cable
Loose plug connector
21 Spreader overloaded.
For weighing spreader only: Mineral
fertiliser spreader is overstrained.
Too much fertiliser in the hopper
22 Unknown status Function
Stop.
Communication problem at Terminal.
possible software error
27 spreading discs rotate
without activation.
Defective or manually switched hydraulic
valve.
28 spreading discs could not be
started.
spreading discs do not rotate.
Blockade
No position message
29 Agitator engine is
overstrained.
Agitator is blocked.
Blockade
Defective connection
30 Before opening the slides, the
spreading discs must be
activated.
Correct software operation.
Start spreading discs
Open metering slider
33 Stop spreading discs and
close metering slides.
You may only change into the system / test
menu area if the spreading mode has been
deactivated.
Stop spreading discs
Close the metering slider