Checking and setting the metering slide
basic settings
RAUCH Landmaschinenfabrik GmbH D-76547 Sinzheim
Customer service hotline: +49 (0)7221 985 250
E-mail: service@rauch.de
Page
2
of
2
27.10.2014
Chapter 310
2. Setting adjustment:
Read the scale position.
Correct setting: Position 85
In case of deviations, release the retention
screws of the metering slide scale and
relocate the scale in such a way that
position 85 is displayed.
Re-tighten the screws when the setting is
correct.
Reattach the actuator bolts and secure
them.
Reassemble the spreading discs.
3. After the basic settings are changed, the metering slide actuators have to be
recalibrated
=> see chapter 4 “Metering slide actuator calibration”