Managing Hardware with CLI Commands
5-16 SmartEdge 100 Router Hardware Guide
Table 5-15 describes the output fields for the show port command (in any mode).
Table 5-16 lists the output fields for the show port command (in any mode) with the detail keyword. Not
all fields apply to all types of ports; in most cases, this command displays only the fields that are applicable
to the type of port. The “Type” and “Slot/Port” field names are not displayed in the output.
Table 5-15 Output Fields for the show port Command
Field Value/Description
Slot/Port:Ch:SubCh slot/port—Slot and port numbers for this port.
Type ethernet—Port type for any port on the system.
State Port status (combination of the Admin state and Line state fields):
Down—Port has been configured to be Up, but is not working.
No card—The I/O carrier card on the circuit board, the MIC, and the port are configured, but
the MIC is not installed.
Unavailable—The I/O carrier card is configured, but the MIC is not configured; or the I/O
carrier card and the MIC are configured, but the MIC does not support this port.
Unconfigured—The I/O carrier card and the MIC are configured, but this port is not
configured.
Up—Port is working (active).
Table 5-16 Output Fields for the show port Command with the detail Keyword
Field Value/Description
Header
Type ethernet—FE or GE port (any version).
Slot/Port slot/port—Slot and port numbers for this port.
state is Port status (combination of the Admin state and Line state fields):
Down—Port has been configured to be Up, but is not working.
No card—Port has been configured, but the MIC is not installed.
Unavailable—Port is not supported by the MIC or the MIC is not configured.
Unconfigured—Port is not configured and down.
Up—Port is working (active).
Port Parameters (in alphabetical order)
Active Alarms N/A—Not applicable to this type of port.
NONE—No alarms are present.
Admin state State of the port as a result of an operator command:
Down—Port is not working.
Unconfigured—Port is not configured and down.
Up—Port is working (active).
Speed Speed of the port.
Dampening Count n—Number of instances this link-dampened FE or GE port went down and came up within the limits set by
the link-dampening feature.
Description Configured description.
Diag Monitor Status of this SFP transceiver with regard to monitoring SFP faults and reporting power readings:
No—SFP cannot monitor its faults nor report power readings.
Yes—SFP can monitor its faults and report power readings.