Managing Hardware with CLI Commands
5-16 SmartEdge 100 Router Hardware Guide
Table 5-15 describes the output fields for the show port command (in any mode).
Table 5-16 lists the output fields for the show port command (in any mode) with the detail keyword. Not
all fields apply to all types of ports; in most cases, this command displays only the fields that are applicable
to the type of port. The “Type” and “Slot/Port” field names are not displayed in the output.
Table 5-15 Output Fields for the show port Command
Field Value/Description
Slot/Port:Ch:SubCh slot/port—Slot and port numbers for this port.
Type ethernet—Port type for any port on the system.
State Port status (combination of the Admin state and Line state fields):
• Down—Port has been configured to be Up, but is not working.
• No card—The I/O carrier card on the circuit board, the MIC, and the port are configured, but
the MIC is not installed.
• Unavailable—The I/O carrier card is configured, but the MIC is not configured; or the I/O
carrier card and the MIC are configured, but the MIC does not support this port.
• Unconfigured—The I/O carrier card and the MIC are configured, but this port is not
configured.
• Up—Port is working (active).
Table 5-16 Output Fields for the show port Command with the detail Keyword
Field Value/Description
Header
Type ethernet—FE or GE port (any version).
Slot/Port slot/port—Slot and port numbers for this port.
state is Port status (combination of the Admin state and Line state fields):
• Down—Port has been configured to be Up, but is not working.
• No card—Port has been configured, but the MIC is not installed.
• Unavailable—Port is not supported by the MIC or the MIC is not configured.
• Unconfigured—Port is not configured and down.
• Up—Port is working (active).
Port Parameters (in alphabetical order)
Active Alarms • N/A—Not applicable to this type of port.
• NONE—No alarms are present.
Admin state State of the port as a result of an operator command:
• Down—Port is not working.
• Unconfigured—Port is not configured and down.
• Up—Port is working (active).
Speed Speed of the port.
Dampening Count n—Number of instances this link-dampened FE or GE port went down and came up within the limits set by
the link-dampening feature.
Description Configured description.
Diag Monitor Status of this SFP transceiver with regard to monitoring SFP faults and reporting power readings:
• No—SFP cannot monitor its faults nor report power readings.
• Yes—SFP can monitor its faults and report power readings.