RE 30126-01-B/08.07 | Manual Hydraulics | Bosch Rexroth AG 17/76
Application: Valve control for the 4WRE6 / 4WRE10 3
3.2 Data exchange between the BODAC software and the VT-VRPD
controller card
Establish an RS-232 connection between the PC and the VT-VRPD so that you can
configure, save and duplicate the desired data for your controller card.
The baud rate (57600 baud) is fixed in the card.
Ø Connect PC to VT-VRPD using an RS-232 cable (1:1 cable)
e.g. cable set: VT-HACD-1x/03.0/HACD-PC, Material-No. R900776897,
length 3 m
Ø Turn on PC and VT-VRPD
Ø Install BODAC.
Ø Start BODAC (see section 4 “BODAC user interface”).
USB converter:
If the PC has no serial port, an USB/RS232 interface converter may be
used. (Can be ordered using material number R901066684.)
3.3 Open or create parameter file
The card is configured depending on the application. The data for configuration and
parameterisation are saved in a file (FILENAME.PARAM) and stored in the predefined
directory \user\.
Assign a file name and save the beginning state.