Error Codes
D418 26 SM
Code Meaning Suggested Cause/Action
0-08
The other end sent RTN
or PIN after receiving a
page, because there
were too many errors
Check the line connection.
Check the FCU - NCU connectors.
Replace the NCU or FCU.
The other end may have jammed, or run out of
paper or memory space.
Try adjusting the tx level and/or cable
equalizer settings.
The other end may have a defective
modem/NCU/FCU; try sending to another
machine.
Check for line problems and noise.
Cross reference
Tx level - NCU Parameter 01 (PSTN)
Cable equalizer - G3 Switch 07 (PSTN)
Dedicated Tx parameters - Section 4
0-14
Non-standard post
message response code
received
Check the FCU - NCU connectors.
Incompatible or defective remote terminal; try
sending to another machine.
Noisy line: resend.
Try adjusting the tx level and/or cable
equalizer settings.
Replace the NCU or FCU.
Cross reference
See error code 0-08.
0-15
The other terminal is not
capable of specific
functions.
The other terminal is not capable of accepting
the following functions, or the other terminal’s
memory is full.
Confidential rx
Transfer function
SEP/SUB/PWD/SID
0-16
CFR or FTT not detected
after modem training in
Check the line connection.
Check the FCU - NCU connectors.

Table of Contents

Other manuals for Ricoh Aficio MP 8001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio MP 8001 and is the answer not in the manual?

Ricoh Aficio MP 8001 Specifications

General IconGeneral
BrandRicoh
ModelAficio MP 8001
CategoryAll in One Printer
LanguageEnglish

Related product manuals