Error Codes
D418 28 SM
Code Meaning Suggested Cause/Action
(default: 200 ms) Check for line noise or other line problems.
Try adjusting the acceptable modem carrier
drop time.
Cross reference
Acceptable modem carrier drop time - G3
Switch 0A, bits 0 and 1
0-23
Too many errors during
reception
Check the line connection.
Check the FCU - NCU connectors.
Replace the NCU or FCU.
Defective remote terminal.
Check for line noise or other line problems.
Try asking the other end to adjust their tx level.
Try adjusting the rx cable equalizer setting
and/or rx error criteria.
Cross reference
Rx cable equalizer - G3 Switch 07 (PSTN)
Rx error criteria - Communication Switch 02,
bits 0 and 1
0-30
The other terminal did
not reply to NSS(A) in AI
short protocol mode
Check the line connection.
Check the FCU - NCU connectors.
Try adjusting the tx level and/or cable
equalizer settings.
The other terminal may not be compatible.
Cross reference
Dedicated tx parameters - Section 4
0-32
The other terminal sent a
DCS, which contained
functions that the
receiving machine
cannot handle.
Check the protocol dump list.
Ask the other party to contact the
manufacturer.
0-52
Polarity changed during
communication
Check the line connection.
Retry the communication.