Service Call Conditions
SM Appendix 3-57 D062/D063/D065/D066
Appendix:
Service Call
Conditions
823
CTL
B
Self-diagnostic error: NIB
[XXXX]: Detailed error code
[6101]
MAC address check sum error
The result of the MAC address check sum does not match the check
sum stored in ROM.
[6104]
PHY IC error
The PHY IC on the controller cannot be correctly recognized.
[6105]
PHY IC loop-back error
An error occurred during the loop-back test for the PHY IC on the
controller.
- 1. Replace the controller.
Self-diagnostic error 4: NVRAM
824 D
One or more of the following
conditions exist:
NVRAM not present.
NVRAM damaged
NVRAM socket damaged
NVRAM defective
Controller board defective
NVRAM backup battery
exhausted
NVRAM socket damaged
Note: In every case, the controller
board must be replaced.
Self-diagnostic Error: Optional RAM
829 D
The optional RAM returned an error
during the self-diagnostic test.
Replace the optional memory
board
Controller board defective
For more details about SC 833, SC834 and other errors, execute SP5990 to print
an SMC report so you can read the error code. The error code is not displayed on
the operation panel. The additional error codes (0F30, 0F31, etc. are listed in the
SMC report.

Table of Contents

Other manuals for Ricoh Aficio MP 8001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio MP 8001 and is the answer not in the manual?

Ricoh Aficio MP 8001 Specifications

General IconGeneral
BrandRicoh
ModelAficio MP 8001
CategoryAll in One Printer
LanguageEnglish

Related product manuals