Service Call Conditions
D062/D063/D065/D066 3-60 SM Appendix
USB I/F Error 1 GW
The USB driver is unstable and generated an error. The USB I/F cannot
be used.
857 D
USB board or controller board defective
Data Encryption Error 1
858 B
These are errors of the HDD Data Encryption Option D377.
0 Key Acquistion
Key could be acquired.
Replace the controller board
1
HDD Key Setting
Error
The key was acquired but the HDD could not be
set.
Turn the machine power off/on several times.
Replace the controller board.
2 NVRAM Read Error
NVRAM data conversion failed (mismatch with
nvram.conf)
Replace the NVRAM
30
NVRAM Before
Replace Error
DFU. May occur during development.
Turn the machine power off/on several times.
Replace the controller board.
31 Other Error
An unexpected error occurred while data was
being converted. This error is the same as SC991.
See SC991 below.
Data Encryption Error 2
859 B
These are errors of the HDD Data Encryption Option D377.
8 HDD Check Error
Data conversion was attempted with no HDD unit
present.
Confirm that HDD unit installed correctly