Service Program Mode Tables
D062/D063/D065/D066 4-102 SM Appendix
[1 to 9999 / 350 / 1]
SC/Alarm Setting
5515
With NRS (New Remote Service) in use, these SP codes can be set to issue an
SC call when an SC error occurs. If this SP is switched off, the SC call is not
issued when an SC error occurs.
001 SC Call
002 Service Parts Near End Call
003 Service Parts End Call
004 User Call
[0 to 1/1/1]
0: Off, 1: On
006 Communication Test Call
007 Machine Information Notice
008 Alarm Notice
[0 or 1 / 1 / - ]
0: Off
1: On
010 Supply Automatic Ordering Call
011 Supply Management Report Call
[0 to 1/0/1]
012 Jam/Door Open Call [0 to 1/1/1]
Memory Clear
5801
Resets NVRAM data to the default settings. Before executing any of these SP
codes, print an SMC Report.
The following data stored in the NVRAM will not be saved to the SD card when
you perform an NVRAM data upload (SP5824).
¾ Total counter value
¾ C/O, P/O counter values
¾ Duplex, A3/DLT/Over 420mm, Stapler, and Scanner counter values