20 February, 2001 USING SERVICE PROGRAM MODES
5-11
Service
Tables
SP4-XXX (Scanner)
4
Mode Number/Name Function/[Setting]
Main Scan Magnification (Scanner)008*
Adjusts the magnification along the main scan direction,
for scanning.
[–1.0 ~ +1.0 / 0.0 / 0.1%/step] IAJ
• Use the ! key to select “+” or “–” before entering the
value
• The specification is 100
±
1.0%
• Main scan magnification is implemented in steps of 0.5.
Accordingly, your input value should be a multiple of 0.5
(–1.0, –0.5, 0, +0.5, or +1.0)
Leading Edge Registration (Scanner)010*
Adjusts the leading edge registration for scanning in
platen mode.
[–5.0 ~ +5.0 / 0.0 / 0.1 mm/step] IAJ
• (–): The image moves toward the leading edge.
• (+): The image moves toward the trailing edge
• Use the ! key to select “+” or “–” before entering the
value
The specification is 2
±
1.5 mm.
Side-to-side Registration (Scanner)011*
Adjusts the side-to-side registration for scanning in platen
mode.
[–10.0 ~ +6.0 / 0.0 / 0.1 mm/step] IAJ
• Increasing the value shifts the image to the right
• Use the ! key to select “+” or “–” before entering the
value
• The specification is 2
±
1.5 mm.
Erase Margin
1 Leading edge
2 Trailing edge
3 Left
012*
4Right
Adjusts the scanning margin individually for each of the
four edges.
[0 ~ 9.0 / 1.0 / 0.1 mm/step] IAJ
It is generally best to adjust the scanning margin as little
as possible, and use the printing margin for image
adjustments.
Scanner Free Run013
Performs a scanner free run with the exposure lamp on.
[0 = No / 1 = Yes]
After selecting “1”, press OK or ' twice to start the run.
Press % to stop.