SCANNER SECTION 20 February, 2001
3-14
Procedure
1. Set the machine to detect 8K/16K originals as follows.
• If the machine is equipped with the platen cover: Access SP mode 5-955-1,
and set the setting to 1 (=Yes). The machine will now detect 8K/16K rather
than B4/B5. (B4-SEF → 8K-SEF; B5-SEF → 16K-SEF; B5-LEF → 16K-LEF)
• If the machine is equipped with the ADF or ARDF: Access SP mode 5-955-2,
and set the setting to 1 (=Yes). The machine will now detect 8K/16K rather
than A3/A4/B4/B5. (A3-SEF/B4-SEF → 8K-SEF; B5-SEF/A4-SEF → 16K-
SEF; B5-LEF/A4-LEF → 16K-LEF)
• Note that making either of the above settings will disable use of SP mode 5-
911.
2. Turn off the power, and remove the exposure glass (☛ 3.4.1).
3. Remove APS senosrs [A, B].
4. Remove screws [C, D] at the new mount positions.
5. Mount the original width sensor into the new position (from where you removed
screw [C]), and screw.
6. Mount the original length sensor into the new position (from where you
removed screw [D]), and screw it.
7. Screw screws back into their original holes.
B039R004.WMF
B039R012.WMF
[A]
[B]
[C]
[D]