USING SERVICE PROGRAM MODES 20 February, 2001
5-24
SP6-XXX (Peripherals)
6
Mode Number/Name Function/[Setting]
ADF Registration
1 Side-to-Side/Front Adjusts the side-to-side registration for the front side of
the original, for ADF mode.
[–7.0 ~ +9.5 / 0.0 / 0.1 mm/step] IAJ
Use the ! key to select “+” or “–” before entering the
value.
2 Leading edge Adjusts the leading edge registration for ADF mode.
[–5.0 ~ +5.0 / 0.0 / 0.1 mm/step] IAJ
0.1 mm/step
Use the ! key to select “+” or “–” before entering the
value.
3 Trailing edge erase Adjusts the trailing edge erase margin for ADF mode.
[–3.0 ~ +3.0 / –1.0 / 0.1 mm/step] IAJ
Use the ! key to select “+” or “–” before entering the
value.
006*
4 Side-to-Side/Rear Adjusts the side-to-side registration for the rear side of
duplex originals, for ADF mode.
[–7.0 ~ +9.5 / 0.0 / 0.5 mm/step] IAJ
Use the ! key to select “+” or “–” before entering the
value.
ADF Sub-scan Magnification007*
Adjusts the actual magnification ratio in the sub-scan
direction, for ADF mode.
[–0.9 ~ +0.9 / 0.0 / 0.1%/step] IAJ
Use the ! key to select “+” or “–” before entering the
value.
ADF Free Run009
Performs an ADF free run .
[0 = No / 1 = Yes]
After selecting “1”, press OK or ' twice to start the run.
Press % to stop.
Stamp Position Adjustment010*
Adjusts the stamp position in the sub-scan direction, for
fax mode.
[–10 ~ +10 / 0 / 1mm/step]
ADF APS Data Display901
Displays the status of the ADF original size sensors.
5.1.12 ADF APS Original Sensor Output Display
ARDF Skew Correction905*
Enables/disables use of skew correction when the ARDF
feeds the rear side of an original.
[0 = No / 1 = Yes]
ARDF Original Curl Adjustment906*
Adjusts the amount of original buckle at the ARDF
registration roller when the ARDF feeds the rear side of an
original.
[–20 ~ +20 / 0 / 1 mm/step]
This SP mode is effective only if SP6-905 is set to “1”.