20 February, 2001 USING SERVICE PROGRAM MODES
5-13
Service
Tables
4
Mode Number/Name Function/[Setting]
4 ODD result Displays the value from the most recent ODD channel
black level adjustment.
[0 ~ 255 / 0 / 1/step] DFU
5 Number of attempts Displays the number of times SBU black level adjustment
was performed before the target values in 4-904-1 and 2
were reached.
DFU
6* Factory setting - EVEN Displays the value of the black level for the EVEN channel
set at the factory.
[0 ~ 255 / 0 / 1/step] DFU
904
7* Factory setting - ODD
Displays the value of the black level for the ODD channel
set at the factory.
[0 ~ 255 / 0 / 1/step] DFU
SBU White Level Adjustment
1* EVEN target This is the reference value for the EVEN channel white
level used for white level adjustment at power-up.
[0 ~ 255 / 0 / 1/step] DFU
Use this mode to re-input the previous value after
performing memory all clear (SP5-801).
2* ODD target
This is the reference value for the ODD channel white
level used for white level adjustment at power-up (set at
the factory).
[0 ~ 255 / 0 / 1/step] DFU
Use this mode to re-input the previous value after
performing memory all clear (SP5-801).
3EVEN result
Displays the value from the most recent EVEN channel
white level adjustment.
[0 ~ 255 / 0 / 1/step] DFU
4 ODD result Displays the value from the most recent ODD channel
white level adjustment.
[0 ~ 255 / 0 / 1/step] DFU
5 Number of attempts Displays the number of times SBU white level adjustment
was performed before the target values in 4-904-1 and 2
were reached.
DFU
6* Factory setting - EVEN
Displays the value of the white level for the EVEN channel
set at the factory.
[0 ~ 255 / 0 / 1/step] DFU
905
7* Factory setting - ODD
Displays the value of the white level for the ODD channel
set at the factory.
[0 ~ 255 / 0 / 1/step] DFU
SBU White Level (EVEN/ODD)
1* Set value This is the reference value for the White Level EVEN/ODD
adjustment carried out at power-up.
[0 ~ 600 / 0 / 1/step] DFU
Use this mode to re-input the previous value after
performing memory all clear (SP5-801).
2 Result
Displays the value from the most recent EVEN/ODD SBU
White Level adjustment.
DFU
906
3* Factory setting Displays the factory-set White Level EVEN/ODD setting.
DFU

Table of Contents