20 February, 2001 IMAGE FUSING AND PAPER EXIT
6-63
Detailed
Descriptions
Copying (North America Model)
Sampling cycle: 1 second
Soft start setting: 3 cycles
Current minus Target
Previous minus Current
–3°
°°
°C or
less
–2°
°°
°C or
–1°
°°
°C
0°
°°
°C
+1°
°°
°C or
+2°
°°
°C
+3°
°°
°C or
more
-3°C or less
100% 100% 100% 100% 0%
From –2°C to –1°C
100% 70% 70% 70% 0%
0°C
100% 50% 30% 30% 0%
From +1°C to +2°C
100% 30% 0% 0% 0%
+3°C or more
100% 0% 0% 0% 0%
Ratio (%): The proportion of time that the fusing lamp power is on
Copying (Europe Model)
Sampling cycle: 1 second
Soft start setting: 10 cycles
Current minus Target
Previous minus Current
–3°
°°
°C or
less
–2°
°°
°C or
–1°
°°
°C
0°
°°
°C
+1°
°°
°C or
+2°
°°
°C
+3°
°°
°C or
more
–3°C or less
100% 100% 100% 0% 0%
From –2°C to –1°C
100% 100% 100% 0% 0%
0°C
100% 100% 100% 0% 0%
From +1°C to +2°C
100% 100% 100% 100% 0%
+3°C or more
100% 100% 100% 100% 0%
Ratio (%): The proportion of time that the fusing lamp power is on
Standby
Sampling cycle: 1 second
Soft start setting: 3 cycles (Europe model: 20 cycles)
Current minus Target
Previous minus Current
–3°
°°
°C or
less
–2°
°°
°C or
–1°
°°
°C
0°
°°
°C
+1°
°°
°C or
+2°
°°
°C
+3°
°°
°C or
more
–3°C or less
100% 100% 0% 0% 0%
From –2°C to –1°C
100% 100% 0% 0% 0%
0°C
100% 100% 0% 0% 0%
From +1°C to +2°C
100% 100% 100% 0% 0%
+3°C or more
100% 100% 100% 0% 0%
Ratio (%): The proportion of time that the fusing lamp power is on