Main SP Tables-3
D117/D118 3-208 SM Appendix
3330 [ID.Sens Coef :Disp]
001 K2(Latest) *ENG Displays the latest value for the sensitivity
correction coefficient (K2 or K5) of ID
sensor.
[0.0000 to 5.0000 / - / 0.0001/step]
011 K5(Latest) *ENG
3331 [ID.Sens Coef :Set]
001 K2: Upp Limit Corr *ENG [-0.20 to 0.40 / 0.07 / 0.01/step]
002 K2: Lwr Limit Corr *ENG [-0.40 to 0.20 / -0.07 / 0.01/step]
003 K2: Upp/Lwr Limit Coef1 *ENG [0.00 to 1.00 / 0.00 / 0.01/step]
004 Kn: Lower *ENG
Sets the upper limit of valid range of
normalized value for normal reflection
light using the sensitivity correction (K5).
[0.00 to 1.00 / 1.00 / 0.01/step]
005 Kn: Upper *ENG
Sets the lower limit of valid range of
normalized value for normal reflection
light using the sensitivity correction (K5).
[0.00 to 1.00 / 0.10 / 0.01/step]
006 K5: Upper *ENG
Sets the upper limit of the sensitivity
correction coefficient (K5).
[0.00 to 10.00 / 5.00 / 0.01/step]
007 K5: Lower *ENG
Sets the lower limit of the sensitivity
correction coefficient (K5).
[0.00 to 1.00 / 0.50 / 0.01/step]
008 K5: Target Point *ENG
Sets correction point (Kn) for sensitivity
correction coefficient (K5).
[0.00 to 1.00 / 0.15 / 0.01/step]
009 K5: Target Voltage *ENG
Sets correction point (delta
Vsp_dif_Dash) for sensitivity correction
coefficient (K5).
[0.00 to 5.00 / 1.63 / 0.01V/step]