SP Mode
Tables
010
Delivery Svr. Capability *CTL [0 to 255 / - / 1 /step]
Changes the capability of the registered that the I/O device registered.
Bit7 = 1 Comment information exits
Bit6 = 1 Direct specification of mail address possible
Bit5 = 1 Mail RX confirmation setting possible
Bit4 = 1 Address book automatic update function exists
Bit3 = 1 Fax RX delivery function exists
Bit2 = 1 Sender password function exists
Bit1 = 1 Function to link MK-1 user and Sender exists
Bit0 = 1 Sender specification required (if set to 1, Bit6 is set to “0”)
011
Delivery Svr Capability
(Ext)
*CTL [0 to 255 / - / x2/step]
Changes the capability of the registered that the I/O device registered.
Bit7 = 1 Address book usage limitation (Limitation for each authorized user)
Bit6 = 1 RDH authorization link
Bit5 to 0: Not used
013
Server Scheme (Primary)
DFU
*CTL [ Up to 6 char / - / -]
This SP is used for the scan router program.
014
Server Port Number
(Primary) DFU
*CTL [1 to 65535 / 80 / 1/step]
This SP is used for the scan router program.
015
Server URL Path (Primary)
DFU
*CTL [ Up to 16 byte / - / 1byte/step]
This SP is used for the scan router program.
016
Server Scheme
(Secondary) DFU
*CTL [ Up to 6 char / - / -]
This SP is used for the scan router program.