AgilityInstallerManual
Page 4-8
System: Controls
Parameter Default
GlobalFollower
NO
YES:Specifiesthatallzones(thatareprogrammedtofollowanExit/EntryDelaytime)
willfollowtheExit/EntryDelaytimeofanyarmedpartition.
NO:Specifiesthatallzones(thatareprogrammedtofollowanEntryDelaytime)will
followtheEntryDelaytimeofonlythepartitionstowhichthey
areassigned.
Summer/Winter
NO
YES:Thesystemautomaticallysetsitstimeofdayclockonehouraheadinthespring(on
thelastSundayinMarch)andonehourbackintheAutumn(onthelastSundayin
October).
NO:Noautomatictimeaccommodationismade.
24HourBypass
NO
YES:Itispossiblefortheusertobypassa24‐hourzone.
NO:Itisnotpossiblefortheusertobypassa24‐hourzone.
TechnicianTamper
NO
YES:ItisnecessarytoentertheInstallerCodetoresetaTamperalarm.Therefore,
resettingaTamperalarmrequirestheinterventionofthealarmcompany.However,the
systemcanstillbeset.
NO:CorrectingtheproblemresetsaTamperalarm,requiringnoalarmcompanyhelp.
TechnicianReset
NO
YES:ItisnecessarytoentertheInstallerCodetoresetanalarmedpartitionafterithas
beendisarmed.Thisrequirestheinterventionofthealarmcompany.
Note:BeforetheReadyLEDcanlightallzoneswithinthepartitionmustbesecured.
NO:OnceanalarmedpartitionisresettheReadyLEDlightswhenallzonesaresecured.
InstallerTamper
NO
YES:AfteraTamperalarm,thesystemisnotreadytoarm.Thisrequirestheintervention
ofthealarmcompany.
NO:AfteraTamperalarmisrestoredthesystemisready.
LowBatteryArm
YES
YES:Allowsarmingofthesystemwhenalowbatteryconditionisdetectedinthemain
unit.
NO:Armingthesystemisdisabledwhenalowbatteryconditionisdetected.