AgilityInstallerManual
Page 4-9
System: Controls
Parameter Default
SirenPre‐Alarm
NO
Specifiesifthesystemwillsendapre‐alarmmessagetothesirenwhileanentrydelay
starts.
YES:Thesystemsendsapre‐alarmsignaltothesirenatthebeginningoftheentrydelay.
Ifthesirendoesnotreceiveacancellationsignalfromthesystemattheendoftheentry
time,thesirengoesintoalarm.
NO:Pre‐Alarmdisabled
Bell30/10
NO
YES:Thesirensceasetosoundfor10secondsaftereach30secondsofoperation.
NO:Thesirensoperatewithoutinterruption.
FireAlarmPattern
NO
YES:Duringafirealarm,thesirensproduceapatternof3shortburstsfollowedbya
briefpause.
NO:Duringafirealarm,theflowofsoundsproducedbythesirenisapatternof2
secondsON,then2secondsOFF.
IMQ
NO
YES:Causesthefollowingparameterstofunctionasfollows:
AutoArmBypass:Ifthereisan openzoneduring theAutoArmprocess,thesystem
willbearmed,andasilentalarmwillbeactivated(unle s s theopenzoneisclosed).
Autilityoutputdefinedas“AutoArmAlarm”isactivated.
Autilityoutputdefinedas“ZoneLossAlarm”isactivated
NO:Causesthefollowingparameterstofunctionasfollows:
AutoArmBypass:IftheAutoArmprogrammingarms thesystemandthereisan
openzoneduringtheautoarm,thesystemwillbypasstheopenzonesandarmthe
system.
Autilityoutputdefinedas“AutoArmAlarm”isdeactivated.
Autilityoutputdefinedas“ZoneLossAlarm”isdeactivated.
DisableIncomingCall
NO
Thisparameterisusedtodisableallincomingcallstryingtocomeinviathevoice
channel(PSTNorGSM).
YES:Incomingcallsfromvoicechannelaredisabled.
NO:Incomingcallsfromvoicechannelareenabled.
Note:IncomingdatacallviatheGSMdatachannelisstillenabled.