AgilityInstallerManual
Page 4-10
System: Controls
Parameter Default
Communication
MSEnableYES
YES:EnablescommunicationwiththeCentralStationtoreportalarms,trouble,and
supervisoryevents.
NO:NocommunicationwiththeCentralStationispossible.ChooseNOforinstallations
thatareNOTmonitoredbyaCentralStation.
ConfigurationSoftwareEnable YES
YES:Enablescommunicationbetweenthealarmcompanyandthesystemusingthe
Configurationsoftware.Thisenablesmodifyinganinstallationʹsconfiguration,obtaining
statusinformation,andissuingMainPanelcommands,allfromaremotelocation.
NO:Disablescommunication,as detailedabove.
FMEnable YES
YES:EnablesFollow‐Mecommunication.
IfboththeMSphonesandtheFMphonesaredefined,thesystemwillfirstcalltheMS
phonesandthentheFMphones.
NO:DisablesFollow‐Mecommunication.
EN50131programming
AuthorizeInstaller
NO
ThisoptionlimitstheInstallerandSub‐installerauthorizationtoaccessthe
programmingmenu.
YES:AGrandMastercodeisrequiredtoauthorizetheinstallertoenterthe
programmingmodefor1hour.
NO:TheInstallerdoesnotneedanauthorizationcode.
OverrideTrouble
YES
Specifiesifthesystem/partitioncanbearmedwhenthereisafaultinthesystem.
YES:Thesystemwillarmevenifthereisafaultinthesystem.
NO:Whentheuserstartsthearmingprocessandthereisasystem‐fault,theusermust
confirmthatheis
awareofallfaultsbeforecontinuingwiththeArmingprocess.
ThisisdoneviatheUsermenuÆActivitiesÆBypassTrouble.
Thesystemwillnotarmduringforcedarmingifafaultoccurredinthesystem