AgilityInstallerManual
Page 4-11
System: Controls
Parameter Default
RestoreAlarm
NO
YES:Theusermustconfirmthatheisawarethatalarmoccurredinthe systembefore
rearmingthesystem.ThesystemwillbeinʺNotReadyʺstatusuntilheconfirmsthe
alarm.ThisisdoneviatheUsermenuÆActivitiesÆAdvancedÆRestoreAlarm.
NO:Theuserdoesnotneedto
confirmthealarmbeforerearmingthesystem.
MandatoryEventLog
NO
YES:Onlymandatoryevents(specifiedintheENstandard)willbedisplayedinthe
EventLog.
NO:AlltheeventswillbedisplayedintheEventLog.
RestoreTroubles
NO
YES:Theusermustmanuallyconfirmthe restoralofeachtroubletoanormalcondition.
ThisisdoneviatheUsermenuÆActivitiesÆAdvancedÆRestoreTroubles.
NO:Therestoralreportofeachtroubleisautomatic.
ExitAlarm
YES
YES:Aviolatedzoneoutsidetheexitroutewillgenerateanalarmduringtheexittime.A
reporttothemonitoringstationforarmingthesystemissentatthebeginningofthe
armingprocedure.
NO:Aviolatedzoneoutsidetheexitroutewillcancelthearmingprocess.Areportto
the
monitoringstationissendattheendofasuccessfularmingprocedure.
EntryDelayedAlarm
NO
ThisfeatureisusedtoreducefalsealarmreportstotheMS.
YES:ThereporttotheMSandthesirenalarmwillbedelayedfor30secondsoruntilthe
endofthepredefinedentrydelay(theshortertimeofthetwo)followingaviolationofa
zoneoutside
theentryroute.
NO:Aviolatedzoneoutsidetheentryroutewillgenerateanalarmduringthe
entrytimeandareportwillbesenttotheMS.
20MinutesSignal
NO
YES:Priortoarmingthesystem,thesystemwillcheckforzonesthatdidnotsenda
signalformorethan20minutes.Thesezoneswillberegardedasnotready.Apartition
assignedwithanotreadyzonecannotbearmed.
NO:Priortoarming,thesystemwillnot
checkwhetherazonedidnotsendasignalfor
morethan20minutes.