AgilityInstallerManual
Page 4-12
System: Controls
Parameter Default
Attenuation
NO
YES:TheAgilityreceiverwillbeattenuatedby6dBduringthecommunicationtest.
NO:TheAgilityreceiverworksinnormaloperationmode.
DD243programming
BypassExit/Entry
YES
YES:ItispossiblefortheusertobypassanExit/Entryzone.
NO:AnExit/Entryzonecannotbebypassed.
EntryDisable
NO
YES:Thealarmconfirmationprocesswillbedisabledwhentheentrytimestarts.
NO:Thealarmconfirmationprocesswillstartwhentheentrytimestarts.
RouteDisable
NO
YES:Thepaneldisablestheentryroutezones(EX/EN,EX(OP)/EN,followersandFinal
Exit)fromparticipatinginthealarmconfirmationprocesswhentheentrytimestarts.
Note:Sequentialconfirmationcanstillbeestablishedfromtwoconfirmedzones,locatedofftheentryroute.
NO:Theentryroutezoneswillparticipateinthealarmconfirmationprocesswhenthe
entrytimestarts.
InstallerResetConfirmation
NO
YES:Aninstallerresetconfirmationisrequiredinordertoresetthesystemaftera
confirmedalarm.ThesystemcannotbearmeduntilanInstallerResetConfirmationis
performed.TheresetcanbedonebyenteringtheAnticodeorenteringtheinstallation
modeorbyperforminga“Installerreset”from
thekeypad.
NO:Anymeanscanbeusedtoarmordisarmthesystem(keypad,remotephone
operationetc.).
KeySwitchLock
NO
YES:OnlyaLatchedKeySwitchzonecanarmordisarmthesystem.
Note:Whenthesystemhasmorethan1zonedefinedasLatchKeySwitch,thearm/disarmoperationwill
occuronlyafterallthesezonesarearmedordisarmed.
NO:Anymeanscanbeusedtoarmordisarmthesystem(keypad,remotephone
operationetc.).