AgilityInstallerManual
Page 4-51
Communication: Monitoring Station
Parameter Default Range
Accounts
AccountNumber
Thenumberthatrecognizesthecustomeratthemonitoringstation.Youcan
defineanaccountnumberforeachmonitoringstation.Theseaccountnumbers
arethe6‐digitnumbersassignedbythecentralstation.
Note:Thesystemacceptshexadecimalaccountnumbers.Tosendanaccountnumberwith
lessthan6digitsusethe“0”digit,forexample:Foraccountnumber1234enter001234.In
thiscasethesystemwillnotsendthe“0”digittothecentralstation.
Tosendthe“0”digitlocatedattheleftsideofthenumberusethe“A”digitinsteadofthe
“0”digit.Forexample,foraccountnumber0407enterA407,for6adigitaccountnumber
001207enterAA1207
CommunicationsFormat
EnablesthesystemtocontacttheMonitoringStationinordertoobtaindetailsof
thecommunicationprotocolusedbythedigitalreceiverforeachaccount.
Thecodesareautomaticallyuploadedwhenthecommunicationformathasbeen
selected:
ContactID:Thesystem allocatesReportCodessupportingAD EMCOContact
(Point)ID
SIA:Thesystem allocatesReportCodessupportingtheSIA(Se cur ity Industry
Association)format
Note:SeeAppendixAforthereportcodeslist.
Controls
AllowstoprogramcontrolrelatedtooperationwiththeMonitoringStation.
Handshake
NO
YES:AllLEDsontheAgilitymainunitlightforonesecondwhenthehandshake
signalisreceivedfromtheCentralStationʹsreceiver.
NO:NoindicationforestablishingcommunicationwiththeCentralStationʹs
receiver.
Kiss‐OffY/N
NO
YES:AllLEDsontheAgilitymainunitlightforonesecondandanaudiblesound
isemittedwhenthekissoffsignalisreceivedfromtheCentralStationʹsreceiver.
NO:NoindicationforestablishingcommunicationwiththeCentralStationʹs
receiver.