AgilityInstallerManual
Page 4-52
Communication: Monitoring Station
Parameter Default Range
Parameters
AllowstoprogramparametersrelatedtooperationwiththeMonitoringStation.
MSRetries
08 0115
ThenumberoftimesthesystemredialstheMonitoringStationafterfailingto
establishcommunication.
AlarmRestore
BTO
SpecifiesunderwhatconditionsanAlarmRestoralisreported.Thisoption
informstheMSofachangeinthespecifiedcondition(s)duringanalarmrestore.
ThesereportsneedavalidReportCode.
OnBellTimeOut(BTO)‐Reportstherestoralaftertheaudib l e alarmtimes
out.
FollowZone‐Reportstherestoralwhen thezoneinwhichthealarmoccurs
returnstoitsnonviolated(secured)state.
AtDisarm‐Repo rtstherestoralwhenthesystem(or thepartitioninwhich
thealarmoccurs)isdisarmed,evenifthe sirenhasalreadytimedou t.
MSTimers
AllowstoprogramtimersrelatedtooperationwiththeMonitoringStation.
PeriodicTest
ThePeriodicTestenablesyoutosetthetimeperiodthatthesystemwill
automaticallyestablishcommunicationtotheMonitoringStationinorderto
checktheconnection.Theperiodictestinvolvessendingtheaccountnumberand
avalidtestreportcode(ContactID602,SIATX).Setthetesttimeand
daily
intervalforPeriodicTestReporting.
AbortAlarm
15sec 0255sec
DefinesthetimedelaybeforereportinganalarmtotheMS.Ifthealarmsystemis
disarmedwithintheAbortWindow,noalarmtransmissionshallbesenttothe
MS.
CancelDelay
5min 0255min
YES:Ifanalarmissentinerror,itispossiblefortheMStoreceiveanCancel
AlarmCode,sentsubsequenttotheinitialAlarmCode.Thishappensifavalid
UserCodeisenteredtoresetthealarmafterthedefinedAbortalarmtime.
Note:CancelAlarmreportcode
shouldbedefined.
NO:NoAbortAlarmCodecanbesentonceanalarmhasbeentriggered.

Table of Contents

Other manuals for Risco Agility

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco Agility and is the answer not in the manual?

Risco Agility Specifications

General IconGeneral
Remote ManagementYes
Mobile AppYes
Voice ModuleOptional
Backup BatteryYes
Two-Way VoiceYes
Event ReportingYes
Remote ControlYes
Siren OutputYes
TypeWireless
CommunicationGSM
CompatibilityRisco accessories
Power SupplyMains powered with battery backup