Communication: Monitoring Station
Parameter Default Range
ListenIn
120 1‐240seconds
ThetimedurationforthemonitoringstationtoListeninandperformvoicealarm
verification.Afterthisperiodthesystemhangsuptheline.
Confirmation
TheconfirmationtimesrelatetotheZoneSequentialConfirmation.
ConfirmStart(Confirmdelaytime)
0 0‐120min
Specifiestha tthesystemcannot startasequentialconfirmation process
untilthetimerhasexpired.Thistimestartswhen thesyst emhassetand
willpreventconfirmedalarmsbeinggeneratedinsituationswhena
personhasbeenaccidentallylockedinthebuilding.
ConfirmTimeWindow
030 30‐60min
Specifiesatimeperiodthatstartswhenanalarmistriggeredforthefirst
time.Ifasecondalarmistriggeredbeforetheendoftheconfirmation
timewindow,thesystemwillsendaconfirmedalarmtothemonitoring
station.
NoArm
0 0‐12weeks
A No Arm code will be sent to the MS if no arming or disarming has been
establishedduringthetimedefined(1‐12weeks).
(0=notactivated)
ReportSplit
TheReportSplitmenucontainsparametersthatenabletheroutingofspecifiedeventsto
uptothreeMSReceivers.(SeeAppendixAReportsCodes)
MSArm/Disarm
ReportsArming/Disarming(meaningClosings/Openings)eventstotheMS
Donotcall(noreport)
Send1st:ReportsOpeningsandClosingstoMS1
Send2nd:ReportsOpeningsandClosingstoMS2
Send3rd:ReportsOpeningsandClosingstoMS3
Sendall:ReportsOpeningsandClosingstothealldefinedMS .
1stBackup2nd:ReportsOpeningsandClosingstoMS1.Ifcommunicationis
notestablished,callsMS2.