AgilityInstallerManual
Page 4-54
Communication: Monitoring Station
Parameter Default Range
MSUrgent
Reportsurgent(alarm)eventstotheCentralMonitoringStation
Donotcall(noreport)
Call1st:ReportsOpeningsandClosingstoMS1
Call2nd:ReportsOpeningsandClosingstoMS2
Call3rd:ReportsOpeningsandClosingstoMS3
Callall:ReportsOpeningsandClosingstoth ealldefinedMS.
1stBackup2nd:ReportsOpeningsandClosingstoMS1.Ifcommunicationis
notestablished,callsMS2
MSNonUrgent
Reportsnon‐urgentevents(supervisoryandtestreports)totheMS
Donotcall(noreport)
Call1st:ReportsOpeningsandClosingstoMS1
Call2nd:ReportsOpeningsandClosingstoMS2
Call3rd:ReportsOpeningsandClosingstoMS3
Callall:ReportsOpeningsandClosingstoth ealldefinedMS.
1stBackup2nd:ReportsOpeningsandClosingstoMS1.Ifcommunicationis
notestablished,callsMS2
ReportCodes(Configurationsoftwareonly)
Enablesyoutovieworprogramthecodestransmittedbythesystemtoreportevents(for
example,alarms,troubles,restores,supervisorytests,andsoon)tothemonitoringstation.
ThecodesspecifiedforeachtypeofeventtransmissionareafunctionoftheCentral
Stationʹsownpolicies.Beforeprogrammingany
codes,itisimportanttochecktheCentral
Stationprotocols.Reportingcodesareassignedbydefault,accordingtotheselected
communicationformatSIAorContactID
Assignsaspecifiedreportcodeforeachevent,basedonthereportingformattothe
monitoringstation.Aneventthatisnotassignedwith
areportcodewillnotbereportedto
themonitoringstation.ForlistofreporteventsrefertoAppendixA.