INFORMATION ABOUT THE USE
6.8. BATTERY CHARGER MODE
When the battery level reaches the lower threshold, the machine stops automatically to protect the battery life.
The lower battery threshold is signalled on the battery display by a red bar blinking in the battery icon.
The current wrapping cycle is completed and then the display shows the alarm E90‑battery low (flat battery).
When the alarm is displayed, the machine can only be moved to the recharging area.
The battery is to be recharged in a place protected from weather conditions, well-ventilated and outside
the working environment.
Follow the instructions carefully.
Use protective goggles
No smoking
Electrolyte is highly corrosive.
In case of contact with the electrolyte thoroughly wash yourself with running water and call the hospital
or seek medical advice - Refer to the battery specific instructions.
Proceed as follows.
1. Switch the machine off.
2. Lift the battery cover (A).
With the additional battery kit, simply replace the basket with empty batteries (see “Battery replacement”) with
the basket containing the charged batteries.
3. Insert the plug into a socket.