EasyManuals Logo

Rockwell Automation Allen-Bradley Ultra3000 Migration Guide

Rockwell Automation Allen-Bradley Ultra3000
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
Rockwell Automation Publication 2198-RM003B-EN-P - November 2020 91
Chapter 6 Application Conversion
Set PR Command2 Data (position command: 4000) by explicit
message ‘Set Attribute Single (16), Class 15, Instance 402, Attribute 1,
UDINT Value (4000)’.
4. Execute the Indexing function by doing the following:
Set the drive to Servo On by explicit message ‘Set Attribute Single (16),
Class 15, Instance 215, Attribute 1, INT Value (1)’.
Set the drive to Servo Off by explicit message ‘Set Attribute Single (16),
Class 15, Instance 215, Attribute 1, INT Value (-1)’.
Trigger Homing by explicit message ‘Set Attribute Single (16), Class 15,
Instance 300, Attribute 1, UINT Value (0)’.
Trigger PR Command1 by explicit message ‘Set Attribute Single (16),
Class 15, Instance 300, Attribute 1, UINT Value (1)’.
Stop the PR Command by explicit message ‘Set Attribute Single (16),
Class 15, Instance 300, Attribute 1, UINT Value (1000)’.
Get the status of PR Command by explicit message ‘Get Attribute
Single (14), Class 15, Instance 300, Attribute 1’.

Other manuals for Rockwell Automation Allen-Bradley Ultra3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley Ultra3000 and is the answer not in the manual?

Rockwell Automation Allen-Bradley Ultra3000 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley Ultra3000
CategoryServo Drives
LanguageEnglish

Related product manuals