5 Description of connections
Figures 1-2-3-4 show connection diagrams.
5.1 Typical installation
1
8
9
2
3
5
5
4
4
6
7
It is the installer's responsibility to verify the adequacy of the cables in relation to the devices used in the
installation and their technical characteristics.
Recommended cable
1 Power supply
H07RN-F 3x1,5 mm
2
double
insulated cable (max 15 m)
H07RN-F 3x2,5 mm
2
double
insulated cable (max 30 m)
2 Motor 1 Cable 4x1,5 mm
2
(max 20 m)
3 Motor 2 Cable 4x1,5 mm
2
(max 20 m)
4 Photocell - Receiver F2ES/F2S Cable 4x0,5 mm
2
(max 20 m)
5 Photocell - Transmitter F2ES/F2S Cable 2x0,5 mm
2
(max 20 m)
6
Key selector R85/60 Cable 3x0,5 mm
2
(max 20 m)
Keypad H85/TTD - H85/TDS
(connecting to H85/DEC - H85/DEC2)
Cable 2x0,5 mm
2
(max 30 m)
H85/DEC - H85/DEC2
(connecting to control unit)
Cable 4x0,5 mm
2
(max 20 m)
The number of conductors increases when using more than one
output contact on H85/DEC - H85/DEC2
7
LED Flashing light R92/LED230 - FIFTHY/230
Power supply 230Vac (40 W max)
Cable 2x1 mm
2
(max 10 m)
Antenna Cable tipo RG58 (max 10 m)
8
Gate open indicator
Power supply 24 Vdc (2 W max)
Cable 2x0,5 mm
2
(max 20 m)
9
Courtesy light
Power supply 230 Vac (100 W max)
Cable 2x1 mm
2
(max 20 m)
Encoder connection (if present) Cable 3x0,5 mm
2
(max 30 m)
SUGGESTIONS: with existing installations, we recommend checking the cross section of the cables and
that the cables themselves are in good condition.